Neutral Grounding Resistors
Grid Resistors
Edgewound Resistors
Wirewound Resistors
Helidyne Resistors
Sales Literature
Price Quotation Request Form
Technical Information and Quote Specifications
Authorized Sales Representatives
CONTACT US
Phone:
(216)
573-7600 or
(216) 642-1230
Fax:
(216)
573-5953
E-Mail:
Industrial Power Resistor Sales
|
Neutral Grounding Resistors
Neutral
Grounding Resistors
* |
^ Back to Top |

Neutral Grounding Resistor with safety enclosure. Rated 2400 volts L-N, 400 amps, 10
seconds.
 |
- Designed in strict accordance with IEEE Standard 32-1972
- Reliable, all stainless steel Helidyne™
resistor elements
- Elements are triple insulated from ground for added safety
- Corrosion resistant aluminized steel enclosures
- Fully factory assembled - no field assembly required
- Internal bushings eliminate the need for costly elevating stands
|
Avtron Neutral Grounding Resistors
are designed to provide added safety to industrial
distribution systems by limiting ground fault current to reasonable
levels. In a typical solidly grounded three phase system, the neutral is
tied directly to earth ground. This can cause high ground fault current
(typically 10,000 to 20,000 amps) and excessive damage to transformers,
generators, motors, wiring, and associated equipment. Inserting an
Avtron Neutral Grounding Resistor between neutral and ground limits
fault current to a safe level (typically 25 to 400 amps) while still
allowing sufficient current flow to operate fault clearing relays |
|
Neutral Grounding Transformers |
^ Back to Top |
 |
Avtron Neutral Grounding Transformers are
similar in design to Avtron Neutral Grounding Resistors and provide high resistance
grounding for medium voltage generators and transformers. The standard package consists of
a single-phase, dry-type, Epoxycast™
transformer plus a secondary power resistor, mounted in a common enclosure.
Neutral Grounding Transformer with front cover removed
(shown left). Rated 2400 volts L-N, 10 amps, 60
seconds, with 15KVA 4160:240 P.T. |
|
Specifications for Ordering: |
^ Back to Top |
|
The following information is required when specifying Avtron Neutral
Grounding Resistors or Avtron Neutral Grounding Transformers:
|
- System Voltage
- Line-to-Neutral Voltage
- Current Rating
- Maximum Time On
|
- Open or Enclosed
- Current Transformer Ratio (if applicable)
- Grounding Transformer KVA Rating (if applicable)
- Special Options
|
|
-->
go to Price Quotation Request Form |
Helidyne (TM) is a trademark of Avtron LoadBank, Inc.
Epoxycast (TM) is a trademark of AFP Transformers