Permanent Load Bank
Model: SPIRIT |
 |
|
The Avtron Spirit Load Bank (LSH) is designed for permanent outdoor
installation when 50 to 150 KW loading is required. It is ideal for
routine load testing of standby diesel generating systems or for factory
production line testing of (UPS) Uninterruptible Power Supplies, or
engine generator sets. Designed for outdoor installation on a concrete
pad, the load bank utilizes a fixed louver on the exhaust opening to
protect the blower motor and resistive elements from weather. A remote
control panel is provided for load bank operation and includes the
necessary controls and status indicators. |
|
Capacity |
Minimum Load
Step Resolution |
Load
Voltage |
Blower
Voltage |
Size |
Weight
(lbs.) |
| 50 to 150KW |
5KW |
208VAC; 3phase;
240VAC; 3phase; 240/480VAC; 3phase; 480VAC; 3phase;
600VAC; 3phase |
208/230/460VAC; 3phase;
60Hz; 1HP
575VAC; 3phase; 60Hz; 1HP |
48"L, 27"W,
35"H |
500 |
|
|
^ Back to Top |
|
Permanent Load Bank
Model: K675A |
 |
|
The Model K675A Load Bank is designed for permanent outdoor installation
when 200 KW to 500 KW of load is required. The K675A series is
designed and built to incorporate the latest state-of-the-art
load bank features. It is ideal for high power resistive loading
of AC generating systems. Designed for outdoor installation, the
load bank utilizes a fixed louver on the exhaust opening to
protect the motor and resistive elements from the weather. |
|
Capacity |
Minimum Load
Step Resolution |
Load
Voltage |
Blower
Voltage |
Size |
Weight
(lbs.) |
200 to
500KW |
5KW |
240/480VAC; 480VAC; 3phase
600VAC; 3phase |
230/460VAC; 460VAC; 3phase; 2 or 5HP
575VAC; 3phase; 2 or 5HP |
61"L, 47"W, 52"H |
800 to
1,000 |
|
|
^ Back to Top |
|
Permanent Load Bank
Model: K875A |
 |
|
The Avtron Model K875A load bank can be utilized independently or as a
modular building block for larger systems to meet a variety
of power testing requirements. This load bank is ideal for
permanent outdoor installation for routine load testing of
standby diesel generating systems or for factory production
line testing of (UPS) Uninterruptible Power Supplies,
turbines, or engine generator sets. It is ideal for high
power resistive loading of AC generating systems. The load
bank features vertical air discharge for installation in
areas where space is at a premium such as the rooftops of
high-rise buildings. Weatherproof exhaust hoods provide
maximum protection to the resistor cases and blower
assemblies. |
|
Capacity |
Minimum Load
Step Resolution |
Load
Voltage |
Blower
Voltage |
Size |
Weight
(lbs.) |
| 750KW |
5 or 50KW |
240/480VAC; 3phase;
480VAC;3phase; 600VAC; 3phase |
(1) 10HP; 460VAC; (1) 10 HP; 575VAC |
40"L, 59"W, 138"H |
1,500 |
| 1000KW |
2,000 |
| 1500KW |
5 or 50KW |
480VAC; 3phase; 600VAC; 3phase |
(2) 10HP; 460VAC;
(2) 10HP; 575VAC |
80"L, 59"W, 156"H |
3,000 |
| 2000KW |
4,000 |
| 2500KW |
50KW |
480VAC; 3phase; 600VAC; 3phase |
(3) 10HP; 460VAC;
(3) 10HP; 575VAC |
120"L, 59"W, 156"H |
5,000 |
| 3000KW |
6,000 |
|
|
^ Back to Top |
Note: Other models with
different KW and Voltage ratings
are available on special order.
Control Power: Typical power required for control circuit operation is
120VAC, 1phase, 60 Hz. If 120VAC, 1phase, 60Hz is not available, a variety of single phase
control transformers can be provided as an option.
Blower Power: Blower power is typically provided by an outside source.
Selected load banks are available with blower power derived from the power source under
test.
Digital Metering:
Avtron Advanced Digital Monitoring System ( *
ADMS ™)
is available as an option for display of Volts, Amps, Frequency, and KW. Includes Communicator EXT™ (TM) data-logging software. (for models 50 KW -
3000 KW)
ADMS
™ is a trademark
of Avtron LoadBank, Inc. Communicator EXT
™ is a trademark of
Electro Industries/Gauge Tech. Specifications are subject to change without notice.
All dimensions and weight are approximate
measurements.
|
Medium Voltage Resistive Load Bank
Model:
K875A-MV |
 |
|
The Avtron Model K875A-MV load bank system provides a convenient and
economical means of testing power sources at utility voltages.
Incorporating an integrally mounted step-down transformer, the
K875A-MV provides resistive load testing for power sources at 2400,
4160, 12,470, or 13,800 volts (other voltages are available). The
single skid mounted load bank system makes it practical for
transportation and set up with single point termination of diesel or
turbine generator sets. It is used for resistive testing medium
voltage power sources in factory production lines or in the field
after installation. |
|
Capacity |
Minimum Load
Step Resolution |
Load
Voltage |
Blower
Voltage |
Size |
Weight
(lbs.) |
| 750-1000KW |
5 or 50KW |
5kVAC to 15kVAC; 3phase |
(1) 10HP; 460VAC |
165"L, 60"W, 148"H |
10,000 |
| 1500-2000KW |
(2) 10HP; 460VAC |
230"L, 60"W, 148"H |
15,000 |
|
|
^ Back to Top |
|
Medium Voltage Resistive Load Bank
Model:
K922A |
 |
|
The Avtron Model K922A resistive load bank is ideal for testing
medium-voltage generators or turbines. Avtron is leading the
industry by offering a true medium-voltage load bank while others
still supply a conventional step down transformer and a low voltage
load bank (typically 480 VAC). A medium-voltage load bank eliminates
the need for a costly step-down transformer, which reduces the
overall package size and installation cost. It is ideal for high
power resistive loading of medium voltage generating systems in
factory production lines or test cells. It is designed for permanent
outdoor mounting. |
|
Capacity |
Minimum Load
Step Resolution |
Load
Voltage |
Blower
Voltage |
Size |
Weight
(lbs.) |
| 3000-7000KW per module |
250, 500, or 1000
KW |
5kVAC; 3phase to 15kVAC; 3phase |
(4) to (8) 10HP; 460VAC |
187"L, 102"W, 192"H
(Typical 4500
KW unit) |
13,000 to 17,000 |
|
|
^ Back to Top |
Note: Other models with
different KW and Voltage ratings
are available on special order.
Control Power: Typical power required for control circuit operation is
120VAC, 1phase, 60 Hz. If 120VAC, 1phase, 60Hz is not available, a variety of single phase
control transformers can be provided as an option.
Blower Power: Blower power is typically provided by an outside source.
Selected load banks are available with blower power derived from the power source under
test.
Digital Metering:
Avtron Advanced Digital Monitoring System ( *
ADMS ™)
is available as an option for display of Volts, Amps, Frequency, and KW. Includes Communicator EXT
™ data-logging software.
ADMS
™ is a trademark
of Avtron LoadBank, Inc. Communicator EXT
™ is a trademark of Electro
Industries/Gauge Tech. Specifications are subject to change without notice.
|