Resistor Technical Information
and Quotation Specifications
Following are typical industrial resistor
applications and additional information needed by Avtron to quote.
(Contact us or use the
Price Quotation Request Form.)
Once answers are received an Avtron Sales
Engineer can determine the resistor assembly most suitable for your
application.
|
Industrial Resistor Applications |
^ Back to Top |
|
A.
NEUTRAL
GROUNDING RESISTORS
Resistor inserted between neutral and ground of a
transformer or generator serves to limit fault current to a safe predetermined level.
|
Information needed to quote:
- System Voltage
- Line-to-Neutral Voltage
- Current Rating
- Maximum Time On
- Open or Enclosed
- Current Transformer Ratio (if applicable)
- Grounding Transformer KVA Rating (if applicable)
- Special Options
|
Options
include:
- Current Transformers
- Potential Transformers
- Disconnect Switches (oil or air
insulated)
- Overcurrent Relays
- Aluminum or Stainless Steel
Enclosures
- Special Paint
- Seismic Qualified Units
- High Altitude Ratings (above 6000
feet)
- Hazardous Location Ratings (Class 1,
Group D, Division II)
|
|
^ Back to Top |
|
B.
MOTOR CONTROL RESISTORS
B.1.
Dynamic Braking Resistor for AC or DC Drive. (Electrical
ratings are usually specified by drive manufacturer.)
|
Information needed to quote:
- Ohms
- Watts
- Enclosed? If yes, indoor or outdoor?
|
|
^ Back to Top |
| B.2.
AC Wound Rotor Induction Motor (also referred to as a slip
ring motor). Resistor is wired into the motor secondary slip rings and provides a soft
start as resistance is removed in steps. |
Information needed to quote:
- Application (ex: hoist, bridge, trolley, pump, conveyor, etc.)
- Motor H.P.
- Secondary volts and amps (from motor nameplate)
- Starting torque (if known)
- Number of speed points (ex: 4 steps of resistance = 5 speeds).
- NEMA duty class (if known)
- Enclosed? If yes, indoor or outdoor?
|
|
^ Back to Top |
| B.3.
AC Squirrel Cage Motor. Resistor is used as a ballast for
soft starting (also called a reduced voltage starter). |
Information needed to quote:
- Application (ex: hoist, bridge, trolley, pump, conveyor, etc.)
- Motor H.P.
- Normal line voltage
- Full Load Amps (F.L.A. from motor nameplate)
- Indoor enclosure is standard.
|
|
^ Back to Top |
| B.4.
DC Series Wound Motor. Current limiting resistor is wired
to the field to control motor current (torque) for starting or stopping. |
Information needed to quote:
- Application (ex: hoist, bridge, trolley, pump, conveyor, etc.)
- Motor H.P.
- Normal line voltage
- Full Load Amps (F.L.A. from motor nameplate)
- Starting torque (if known)
- Number of speed points (ex: 3 steps of resistance = 4 speeds).
- For Dynamic Lowering (typically a hoist) - need the name of the control manufacturer.